Flow cytometry analysis · Beta release coming soon
From FCS files to gated populations and statistics.
ScriptaCyte is a desktop application for the analysis of flow cytometry experiments. It brings acquisition quality control, compensation, channel scaling, gating and population statistics into a single workspace, applied consistently across every sample. All data remain on the user's computer.
Illustration of the ScriptaCyte workspace.
Local data processing
Files are read and analysed on the local computer. No upload or account is required.
Verified against reference standards
Gate evaluation is verified against the ISAC Gating-ML 2.0 compliance suite, and scale transforms against reference values.
Open file formats
FCS 2.0, 3.0 and 3.1 input. Gates are exchanged as Gating-ML 2.0 and statistics are exported as CSV.
Workflow
A complete workflow from acquisition to statistics
Each stage is recomputed from the raw events. A change to compensation or to a channel's scale is carried through to every dependent plot, gate and statistic.
Import
FCS files are imported and organised into groups. A single analysis file holds the complete experiment.
Quality control
Event rate and per-channel signal drift are assessed over the acquisition against configurable thresholds. Unstable intervals can be excluded.
Compensation
The spillover matrix stored in the file is applied, or a matrix is calculated from single-stained controls. Individual coefficients can be adjusted against the data.
Scaling
Linear, logarithmic, logicle, arcsinh and hyperlog scales are set per channel. Existing gates are preserved when a channel is rescaled.
Gating
Gates are drawn on plots arranged on a worksheet. Each gate defines a population in the hierarchy and is applied to every sample in the group.
Statistics
Frequencies, counts and medians are reported for every population in every sample, with export to CSV.
Features
Capabilities of the beta release
The capabilities listed below are included in the beta release.
Plots
- Dot, pseudocolour density and contour plots, with outliers shown on contours
- Histograms with population overlays
- Worksheet layout with movable, resizable plots
- Responsive performance on files containing millions of events
Gates
- Rectangle, ellipse, polygon and quadrant gates
- Range gates on histograms, with open bounds
- Boolean gates combining other gates (AND, OR, NOT)
- Direct editing, with immediate update of dependent populations and statistics
Compensation
- Spillover matrix read from the FCS file
- Automatic calculation from single-stained controls, with review before application
- N×N matrix overview, with adjustment of individual pairs
- Matrices assigned per group or per sample
Scaling
- Linear, logarithmic, logicle, arcsinh and hyperlog scales
- Per-channel parameters, adjusted against the data
- Ratio parameters derived from two channels
- Off-scale events retained and counted at the axis limit
Batch analysis
- A single gating strategy applied across each group
- Per-sample review of gate placement
- Population-by-sample statistics table
- Acquisition quality control for each file
Dimensionality reduction
- PCA, UMAP and t-SNE of any population
- Colouring by any marker
- Gating on the resulting maps
- Computed locally
Planned for subsequent releases: spectral unmixing from raw detector data, and figure export.
Standards
Conformance with Gating-ML 2.0
Gate membership is evaluated as defined by the ISAC Gating-ML 2.0 standard and verified against the standard's compliance suite, so that a gating strategy yields the same populations in other conforming software.
Gates imported from Gating-ML remain editable wherever the representation is exact and are otherwise retained as read-only gates; no gate is approximated. On export, any gate that cannot be represented is reported together with the reason.
- Input
- FCS 2.0, 3.0 and 3.1, with byte order, data type, gain and logarithmic amplification applied as specified
- Gates
- Gating-ML 2.0 import and export, including scales, ratio parameters and compensation matrices
- Statistics
- CSV, one row per population and sample
- Analysis file
.scyte, containing groups, compensation, scales, gates and worksheet layout- Platforms
- macOS and Windows
AI integration
AI-assisted analysis through the Model Context Protocol
ScriptaCyte includes a Model Context Protocol (MCP) server, through which an AI model selected by the user can operate the application. Requests are made in natural language. The model's actions are carried out in the open workspace, where they remain visible and editable.
- Read access
- Samples and groups, the gate hierarchy, statistics, histograms, plot images and acquisition quality control
- Operations
- File import, gate creation and editing, application of gates across a group, compensation from controls, channel scaling, exclusion of acquisition intervals, dimensionality reduction and worksheet layout
- Output
- The analysis file, statistics as CSV and gates as Gating-ML 2.0
- Compatibility
- MCP clients, including Claude Desktop, Claude Code and Codex. Connection details are provided in Settings.
Gates created by a model are standard gates, and can be reviewed, adjusted or removed in the same way as any other.
The server is disabled by default and accepts connections from the local computer only. When it is enabled, the connected model has access to the open project, and data are shared with that model's provider under its terms. A locally hosted model retains all data on the computer.
“Gate the lymphocytes, separate the T cells into CD4 and CD8 subsets, and report CD69 expression in each subset for every sample.”
Resources
Panel design resources
Browser-based tools, freely available and independent of the application.
Spectra viewer and panel planner
Compares fluorophore excitation and emission spectra against the lasers and detectors of a specified cytometer, and estimates spillover and spectral similarity for a panel. Panels can be shared by link or exported as CSV.
Open the spectra viewerAvailability
Beta release
The first public beta of ScriptaCyte will be released shortly for macOS and Windows, and will include the capabilities described on this page.
To be notified when the beta becomes available, contact ScriptaScientific.
Beta program
Coming soon
- Desktop application for macOS and Windows
- Quality control, compensation, scaling and gating
- Population statistics with CSV export
- Gating-ML 2.0 import and export
- PCA, UMAP and t-SNE
- MCP server for AI-assisted analysis
- Local data processing
FAQ
Frequently asked questions
When will the beta be available?
The first public beta will be released shortly for macOS and Windows. Notification can be requested under Availability.
Where are data stored?
On the local computer. FCS files are read from disk and the analysis is saved as a .scyte file. No data are uploaded. When an AI model is connected, that model has access to the open project.
Which file formats are supported?
FCS 2.0, 3.0 and 3.1 files from conventional cytometers, and unmixed FCS files from spectral instruments. Gates can be imported from any software that exports Gating-ML 2.0.
Are spectral data supported?
Spectral data unmixed by the instrument software are supported. Unmixing from raw detector data is planned for a subsequent release.
Is an AI model required?
No. Every analysis step is available through the interface. The MCP server is optional and disabled by default.
How does ScriptaCyte relate to ScriptaGraph?
ScriptaCyte produces population statistics; ScriptaGraph provides statistical analysis and figure preparation. Statistics are transferred as CSV.
Is the spectra viewer part of the application?
No. The spectra viewer is a separate, freely available web tool that uses reference spectra from FPbase. It does not access or transmit user data.